Benign versus malignant nodular breast lesion by using elastosonography: preliminary report
Purpose: To assess the diagnostic accuracy of elastography in the characterization of nodular breast lesions. Material and Method: A sample of sixty-three patients with nodular lesions was analyzed between April and December 2007. The elastographic examinations were made using a Hitachi EUB8500 device. In the study were included the patients with a pathological diagnosis and/or patients with known nodular lesion stable for at least two years. Lesions were classified and scored and the sensibility and specificity of elastography calculated. The strain ratio of breast lesions (fat lesion ratio) was calculated by using the software of Hitachi EUB8500 device and also using the ImageProcessing program. Results: The prevalence of malign breast lesion was of 60% with a 95% confidence interval (95%CI) of [48% –72%]. The sensibility and specificity for elasography were almost 87% (95% CI [73% –95%]) and 84% (95% CI [66% –94%]), respectively. The accuracy of elasography was of 86% (95% CI [75% –93%]), with a probability of a wrong positive test of 11% (95% CI [4% –24%] and a probability of wrong negative test of 19% (95% CI [8% –37%]. The ROC analysis of the strain ratio calculated with the Hitachi EUB8500 device showed that the maximum sensibility (of 100%) and specificity (of 71%) is obtained to a cutoff value of 5.06. The cutoff value for the maximum specificity (100%) and a corresponding sensibility of 12% revealed to be at 110.20. The ROC analysis of the strain ratio calculated with the ImageProcessing program showed that the maximum sensibility (of 100%) and specificity (of 50%) is obtained to a cutoff value of 1.59. The cutoff value for the maximum specificity (100%) and a corresponding sensibility of 12% revealed to be at 3.94. Conclusion: The sensibility and specificity of elastography is comparable with that of 2D ultrasonography. The diagnosis confidence could be increased by calculating the strain ratio. If the strain ratio is calculated with Hitachi EUB8500 software a value less than 5.06 shown the benign nature of the lesion and a value greater than 97.21 shown malignancy. The corresponding values for the strain ratio calculated with ImageProcessing program were 1.63 (benignity) and 3.55 (malignancy) respectively. Acknowledgements: The home made program was designed by Technical University of Cluj-Napoca as a part of a ElastoBreast research grant (CEEX/VIASAN/149/2006).
Related projects
No projects linked.
Attachments
No attachments yet.