Digital Charge-Mode Control with Adaptive Valley Current Estimation for a Buck Converter
This paper presents a digital sensorless charge mode controller for a low-voltage synchronous buck converter. The input-current charge is reconstructed from sampled input and output voltages, the applied PWM duty ratio, and power-stage parameters, avoiding a physical current sensor. The controller combines a digital Type-II voltage loop, charge-based inner modulation, transient-adaptive valley-current reconstruction, bounded post-startup equivalent-loss calibration, and input voltage-dependent current-feedback scaling over a 6–18 V input range. MATLAB small-signal analysis is used for controller design and loop-gain assessment, while Cadence AMS simulations verify the synthesized gate-level controller and DPWM together with Verilog-A models of the ADC, gate driver, and power switches. Stable load and line regulation is obtained, with a worst case output-voltage peak deviation below 56 mV.
Authors
Related projects
Attachments
No attachments yet.